The impact of suboptimal bowel preparation on adenoma miss rates and the factors associated with early repeat colonoscopy
Background
There are no guidelines for the recommended interval to the next examination after colonoscopy with suboptimal bowel preparation.
Objective
To identify factors associated with early repeat colonoscopy after initial examinations with suboptimal preparations and to measure adenoma miss rates in this context.
Design
Retrospective study.
Setting
Hospital-based endoscopy unit.
Patients
Bowel preparation quality was recorded in 12,787 patients.
Results
Of 12,787 colonoscopies, preparation quality was suboptimal (poor or fair) in 3047 patients (24%). Among these 3047 patients, repeat examination was performed in <3 years in 505 (17%). Factors associated with early repeat colonoscopy included lack of cecal intubation (odds ratio [OR] 3.62, 95% confidence interval [CI], 2.50-5.24) and finding a polyp (OR 1.55, 95% CI, 1.17-2.07). Among 216 repeat colonoscopies with optimal preparation, 198 adenomas were identified, of which 83 were seen only on the second examination, an adenoma miss rate of 42% (95% CI, 35-49). The advanced adenoma miss rate was 27% (95% CI, 17-41). For colonoscopies repeated in <1 year, the adenoma and advanced adenoma miss rates were 35% and 36%, respectively.
Limitations
Single-center, retrospective study.
Conclusion
Although a minority of patients undergo early repeat examination after colonoscopies done with suboptimal bowel preparation, the miss rates for colonoscopies done with suboptimal bowel preparation were high, suggesting that suboptimal bowel preparation substantially decreases colonoscopy effectiveness and may mandate an early follow-up examination.
Abbreviations: CI, confidence interval, CRC, colorectal cancer, OR, odds ratio
To access this article, please choose from the options below
DISCLOSURE: B. Lebwohl was supported by the National Cancer Institute (T32-CA095929). No other financial relationships relevant to this publication were disclosed.
If you would like to chat with an author of this article, you may contact Dr Lebwohl at BL114@columbia.edu.
See CME section; p. 1254.
PII: S0016-5107(11)00120-9
doi:10.1016/j.gie.2011.01.051
© 2011 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.