Current affiliations: Minnesota Gastroenterology and the University of Minnesota Department of Gastroenterology (R. A. G.), Plymouth, Minnesota, USA, Mayo Clinic School of Medicine, Department of Gastroenterology and Hepatology, Developmental Endoscopy Unit (C. J. G.), Rochester, Minnesota, USA, Torax Medical, Inc (J. G., W. S., T. B.), Maple Grove, Minnesota, USA, University of Southern California School of Medicine, Division of Surgery (T. R. D.), Los Angeles, California, USA

Received 27 April 2007; accepted 2 July 2007.

Plymouth, Rochester, Maple Grove, Minnesota, Los Angeles, California, USA

Background

The success of fundoplication surgery varies widely; furthermore, complications after fundoplication can be common. We introduced a new device to treat GERD: biomechanical augmentation of the lower esophageal sphincter (LES) by use of a magnetic reinforcing appliance.

Objectives

The aim was to determine whether a magnetic appliance could safely increase LES pressure, maintain a closed sphincter except during swallowing and belching, and increase the gastric yield pressure in a porcine model.

Design

Ex vivo work-assessed design variables that would augment the reflux barrier yet still preserve swallow function. Porcine acute and chronic (44 weeks) postimplant studies were also performed. A single animal underwent planned device removal.

Main Outcome Measurements

Gastric yield pressure, animal behavior, endoscopy, barium studies, balloon expansion studies, esophageal manometry, and histology.

Results

Gastric yield pressure correlated with increasing magnetic forces (R2 = 0.5608, P < .001). The sphincter augmentation device was safe in all animals, with no observed effect on eating behavior and normal weight gain. The mucosa of the esophagus appeared normal at all intervals, and there was no device migration or significant tissue inflammation. The average LES pressure rose after implantation (P < .005). Balloon and barium studies demonstrated a closed sphincter with normal opening of the gastroesophageal junction during swallowing.

Conclusions

Magnetic sphincter augmentation is a novel approach for the treatment of GERD. This study demonstrates the safety and feasibility of such a device in a porcine model. Further investigation of this device for the treatment of GERD in humans seems warranted.

Abbreviations: GE, gastroesophageal, LES, lower esophageal sphincter

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Presented in part at Digestive Disease Week, May 21-24, 2006, Los Angeles, California.

PII: S0016-5107(07)02402-9

doi:10.1016/j.gie.2007.07.027

Gastrointestinal Endoscopy
Volume 67, Issue 2 , Pages 287-294, February 2008