Gastrointestinal Endoscopy
Volume 67, Issue 2 , Pages 280-286, February 2008

Narrow-band imaging colonoscopy—a pilot feasibility study for the detection of polyps and correlation of surface patterns with polyp histologic diagnosis

Current affiliations: Division of Gastroenterology and Hepatology (A.R., A.B., S.W., P.C., P.S.) and Department of Pathology (D.H.M., R.C.), Veterans Affairs Medical Center and University of Kansas School of Medicine, Kansas City, Missouri, USA

Received 17 April 2007; accepted 17 July 2007. published online 03 January 2008.

Kansas City, Missouri, USA

Background

Colonoscopy is the preferred screening method for colorectal cancer. However, it has a substantial miss rate for colon polyps, and several techniques have been attempted to improve this limitation. Narrow-band imaging (NBI) is a novel technology that enhances the visualization of surface mucosal and vascular patterns.

Objective

The aim of this study was to determine the detection rate of additional polyps by NBI after removal of polyps visualized by standard white light colonoscopy (WLC) and to correlate the surface mucosal and vascular patterns with polyp histologic diagnosis.

Design

This was a prospective pilot feasibility study.

Setting

Kansas City Veterans Affairs Medical Center.

Patients

Subjects referred for screening colonoscopy were prospectively enrolled.

Methods

Subjects underwent colonoscopy after enrollment. After intubation of the cecum, colonic segments were sequentially examined, initially with WLC with removal of polyps followed by re-examination of the same segment with NBI. Additional polyps seen with NBI were photographed for their surface patterns and then removed. The total number of polyps visualized by WLC and NBI was calculated and the surface patterns were then correlated with polyp histologic features.

Results

Forty patients were enrolled in the study, all men, 32 white. The mean age was 62 years. A total of 72 polyps were detected by WLC (43 tubular adenoma, 28 hyperplastic polyps), whereas NBI detected an additional 51 polyps, of which 29 were tubular adenomas and 22 were hyperplastic. Five different surface/vascular patterns were observed: fine capillary network with absent mucosal pattern, circular pattern with dots, round/oval pattern, tubular pattern, and gyrus pattern. The sensitivity, specificity, and overall accuracy of the first two patterns for hyperplastic polyps were 86%, 96%, and 92%, respectively, and of the latter three patterns for tubular adenomas were 96%, 86%, and 92%, respectively.

Conclusions

This pilot study demonstrates the feasibility of polyp detection and histologic correlation with NBI. These findings need to be confirmed in future randomized controlled trials.

Abbreviations: NBI, narrow-band imaging, WLC, white light colonoscopy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0016-5107(07)02409-1

doi:10.1016/j.gie.2007.07.036

Gastrointestinal Endoscopy
Volume 67, Issue 2 , Pages 280-286, February 2008