Gastrointestinal Endoscopy
Volume 71, Issue 2 , Pages 327-334 , February 2010

Characterization of forces applied by endoscopists during colonoscopy by using a wireless colonoscopy force monitor

Presented at Digestive Disease Week; May 30 to June 4, 2009, Chicago, Illinois (Gastrointest Endosc 2009;69:AB213-AB214).

Received 30 March 2009 ,Accepted 27 August 2009.

References 

  1. Screening for colorectal cancer: U.S. Preventive Services Task Force recommendation statement. Ann Intern Med. 2008;149:627–637
  2. Levin B, Lieberman DA, McFarland B, et al. Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: a joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology. CA Cancer J Clin. 2008;58:130–160
  3. Seeff LC, Manninen DL, Dong FB, et al. Is there endoscopic capacity to provide colorectal cancer screening to the unscreened population in the United States. Gastroenterology. 2004;127:1661–1669
  4. Lieberman D. Screening, surveillance, and prevention of colorectal cancer. Gastrointest Endosc Clin N Am. 2008;18:595–605xi
  5. Seeff LC, Richards TB, Shapiro JA, et al. How many endoscopies are performed for colorectal cancer screening? Results from CDC's survey of endoscopic capacity. Gastroenterology. 2004;127:1670–1677
  6. Rex DK, Johnson DA, Anderson JC, et al. American college of gastroenterology guidelines for colorectal cancer screening 2008. Am J Gastroenterol. 2009;104:739–750
  7. Rex DK. Colonoscopy: the dominant and preferred colorectal cancer screening strategy in the United States. Mayo Clinic Proc. 2007;82:662–664
  8. Marbet UA, Bauerfeind P, Brunner J, et al. Colonoscopy is the preferred colorectal cancer screening method in a population-based program. Endoscopy. 2008;40:650–655
  9. Robertson RH, Burkhardt JH, Powell MP, et al. Trends in colon cancer screening procedures in the US Medicare and Tricare populations: 1999-2001. Prev Med. 2006;42:460–462
  10. Clarke GA, Jacobson BC, Hammett RJ, et al. The indications, utilization and safety of gastrointestinal endoscopy in an extremely elderly patient cohort. Endoscopy. 2001;33:580–584
  11. Rex DK. Quality in colonoscopy: cecal intubation first, then what?. Am J Gastroenterol. 2006;101:732–734
  12. Zauber AG, Winawer SJ. High-quality colonoscopies must be an integral part of screening and surveillance programs. Gastroenterology. 2006;130:620–621
  13. Rex DK, Petrini JL, Baron TH, et al. Quality indicators for colonoscopy. Am J Gastroenterol. 2006;101:873–885
  14. Rex DK. Who is the best colonoscopist?. Gastrointest Endosc. 2007;65:145–150
  15. Principles of training in gastrointestinal endoscopy. From the ASGE. American Society for Gastrointestinal Endoscopy. Gastrointest Endosc. 1999;49:845–853
  16. Appleyard MN, Mosse CA, Mills TN, et al. The measurement of forces exerted during colonoscopy. Gastrointest Endosc. 2000;52:237–240
  17. Wu TK. Occult injuries during colonoscopy. Measurement of forces required to injure the colon and report of cases. Gastrointest Endosc. 1978;24:236–238
  18. Korman J, Brandt L, Marino G, et al. Colonoscopy Skill Score: Results of Expert Skill Testing [abstract]. Gastrointest Endosc. 2007;65:AB327
  19. Aslinia F, Uradomo L, Steele A, et al. Quality assessment of colonoscopic cecal intubation: an analysis of 6 years of continuous practice at a university hospital. Am J Gastroenterol. 2006;101:721–731
  20. Radaelli F, Meucci G, Sgroi G, et al. Technical performance of colonoscopy: the key role of sedation/analgesia and other quality indicators. Am J Gastroenterol. 2008;103:1122–1130
  21. Tran Cao HS, Cosman BC, Devaraj B, et al. Performance measures of surgeon-performed colonoscopy in a Veterans Affairs medical center. Surg Endosc. 2009;
  22. Enoka R. Neuromechanics of human movement. 4th Ed. Champaign, IL: Human Kinetics:. 2008;
  23. Arora G, Mannalithara A, Singh G, et al. Risk of perforation from a colonoscopy in adults: a large population-based study. Gastrointest Endosc. 2009;69:654–664
  24. Bokemeyer B, Bock H, Huppe D, et al. Screening colonoscopy for colorectal cancer prevention: results from a German online registry on 269000 cases. Eur J Gastroenterol Hepatol. 2009;21:650–655
  25. Skipworth JR, Raptis DA, Rawal JS, et al. Splenic injury following colonoscopy—an underdiagnosed, but soon to increase, phenomenon?. Ann R Coll Surg Engl. 2009;91:W6–11
  26. Shergill AK, Asundi KR, Barr A, et al. Pinch force and forearm-muscle load during routine colonoscopy: a pilot study. Gastrointest Endosc. 2009;69:142–146
  27. Cohen J, Cohen SA, Vora KC, et al. Multicenter, randomized, controlled trial of virtual-reality simulator training in acquisition of competency in colonoscopy. Gastrointest Endosc. 2006;64:361–368
  28. Eversbusch A, Grantcharov TP. Learning curves and impact of psychomotor training on performance in simulated colonoscopy: a randomized trial using a virtual reality endoscopy trainer. Surg Endosc. 2004;18:1514–1518
  29. Yi SY, Ryu KH, Na YJ, et al. Improvement of colonoscopy skills through simulation-based training. Stud Health Technol Inform. 2008;132:565–567
  30. Shah SG, Thomas-Gibson S, Brooker JC, et al. Use of video and magnetic endoscope imaging for rating competence at colonoscopy: validation of a measurement tool. Gastrointest Endosc. 2002;56:568–573
  31. Williams C, Guy C, Gillies D, et al. Electronic three-dimensional imaging of intestinal endoscopy. Lancet. 1993;341:724–725
  32. Gerson LB, Van Dam J. Technology review: the use of simulators for training in GI endoscopy. Gastrointest Endosc. 2004;60:992–1001
  33. Sedlack RE, Kolars JC. Colonoscopy curriculum development and performance-based assessment criteria on a computer-based endoscopy simulator. Acad Med. 2002;77:750–751
  34. Thomas-Gibson S, Bassett P, Suzuki N, et al. Intensive training over 5 days improves colonoscopy skills long-term. Endoscopy. 2007;39:818–824

 DISCLOSURE: Grant support from the National Institute of Diabetes and Digestive and Kidney Diseases grant 2R44 DK068936-02A1. The following authors disclosed financial relationships relevant to this publication: L. Y. Korman: Patent holder, Artann Laboratories; S. Tsuryupa: Patent holder and employee, Artann Laboratories; A. Sarvazyan: Patent holder and employee, Artann Laboratories; V. Egorov: Employee of Artann Laboratories; B. Corbin: Employee of Artann Laboratories; N. Sarvazyan: Employee of Artann Laboratories. M. Anderson disclosed no financial relationship relevant to this publication.

 If you would like to chat with an author of this article, you may contact Dr. Korman at louis.korman@verizon.net.

PII: S0016-5107(09)02429-8

doi: 10.1016/j.gie.2009.08.029

Gastrointestinal Endoscopy
Volume 71, Issue 2 , Pages 327-334 , February 2010