Background

A redundant colon can lead to incomplete colonoscopy. A variety of tools and techniques are available to complete colonoscopy but have limitations.

Objective

To determine the feasibility and safety of using a spiral overtube to complete a difficult colonoscopy.

Design

Retrospective review of a prospectively collected database.

Setting

Single tertiary institution.

Patients

Twenty-four patients with incomplete colonoscopy because of redundant colons underwent 26 procedures. The median age was 68 years, and 58% were men.

Interventions

All patients underwent colonoscopy performed with a 90-cm flexible threaded overtube and a variable-stiffness pediatric colonoscope. Four individuals (18%) required exchanging the colonoscope for an enteroscope.

Main Outcome Measurements

Successful cecal intubation, polyp identification and removal, time to reach the cecum, sedation needed, and complications.

Results

Cecal intubation was achieved in 22 patients (92%). Failures occurred in 2 patients with large hernias. The median time from insertion of the colonoscope to reaching the cecum was 14.5 minutes. All procedures were performed by using conscious sedation with midazolam (median dose 7 mg) and fentanyl (median dose 150 μg). Significant findings were encountered in 17 of 22 patients (77%) including 1 cancer and 2 advanced polyps. A median of 3 polyps was removed from each patient who had polyps. All noncancerous polyps were removed during the procedure. There were no complications.

Limitations

Retrospective design, no control group, single center.

Conclusion

Spiral overtube–assisted colonoscopy can enable cecal intubation in the majority of patients in whom standard colonoscopy fails because of a redundant colon.

Abbreviation: BMI, body mass index, SOAC, spiral overtube–assisted colonoscopy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 DISCLOSURE: The authors disclosed no financial relationships relevant to this publication.

 If you would like to chat with an author of this article, you may contact Dr. Schembre at drew.schembre@swedish.org.

PII: S0016-5107(10)02409-0

doi:10.1016/j.gie.2010.11.047

Gastrointestinal Endoscopy
Volume 73, Issue 3 , Pages 515-519, March 2011