In vitro evaluation of wire integrity and ability to reprocess single-use sphincterotomes☆☆☆★★★
Abstract
Background: Sphincterotomes are currently marketed as one-time-use items and constitute considerable cumulative expense in a busy endoscopy unit. It is uncertain whether these accessories can be safely reprocessed without loss of form and function. Methods: We studied disposable sphincterotomes (five 5F, five 6F) in vitro as to their durability, electrical integrity, and ability to be adequately cleaned both manually and with ethylene oxide after contamination with 10 5 to 106 Mycobacterium chelonei. Results: Seven of the 10 sphincterotomes withstood the rigors of reuse; three 6F sphincterotomes developed wire fracture between four and eight uses. Electrical integrity, as measured by an electrosurgical analyzer, remained intact up to time of breakage in all sphincterotomes. Manual cleaning followed by glutaraldehyde soak resulted in residual mycobacterial colonies in five 6F sphincterotomes and a single 5F sphincterotome. No instrument had residual organisms cultured following manual cleaning and ethylene oxide sterilization. Conclusions: The authors conclude that one-time-use sphincterotomes have the potential for safe reuse. (Gastrointest Endosc 1996;45:117-21.)
To access this article, please choose from the options below
☆ From the Sections of Gastroenterology, Clinical Lab and Biomedical Engineering, Virginia Mason Medical Center, Seattle, Washington.
☆☆ Reprint requests: Richard A. Kozarek, MD, Gastroenterology, Virginia Mason Medical Center, 1100 Ninth Ave., PO Box 900 (C3-GAS), Seattle, WA 98111.
★ Availability of Journal back issues: As a service to our subscribers, copies of back issues of Gastrointestinal Endoscopy for the preceding 5 years are maintained and are available for purchase from Mosby until inventory is depleted at a cost of $12.00 per issue. The following quantity discounts are available: 25% off on quantities of 12 to 23, and one third off on quantities of 24 or more. Please write to Mosby–Year Book, Inc., Subscription Services, 11830 Westline Industrial Dr., St. Louis, MO 63146-3318, or call (800) 453-4351 or (314) 453-4351 for information on availability of particular issues. If unavailable from the publisher, photocopies of complete issues may be purchased from UMI, 300 N. Zeeb Rd., Ann Arbor, MI 48106 (313) 761-4700.
★★ 37/1/77057
PII: S0016-5107(97)70232-3
© 1998 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
