      Background: Although previous studies have documented that single-channel sphincterotomes can be sterilized and used up to 10 times, no studies have prospectively evaluated the reuse of disposable sphincterotomes. Methods: Five- and six-French double-channel sphincterotomes marketed as one-time-use only were manually cleaned, sterilized with ethylene oxide, and used up to 10 times. Over a 1-year period, total number of uses as a cannulation or cutting device, reason for sphincterotome dysfunction, possible infectious complications were evaluated, and cost-savings associated with reuse were evaluated. Results: The mean number of times sphincterotomes could be used in our institution was 3.4; a broken or stiff cutting wire was the main reason for discard. There were two infectious complications during the study period. Both were experienced by patients with unrelieved obstruction treated with new sphincterotomes. Contingent on the method used, total savings related to sphincterotome reuse was approximately $66,000. Conclusions: Double-channel sphincterotomes marketed as one-time-use items can be reused safely when properly cleaned. Reuse was associated with significant cost savings in our institution. (Gastrointest Endosc 1999;49:39-42.)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Gastrointestinal Endoscopy
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Kozarek RA
        • Sumida SE
        • Raltz SL
        • Merriam LD
        • Irizarry D
        In vitro evaluation of wire integrity and ability to reprocess single-use sphincterotomes.
        Gastrointest Endosc. 1996; 45: 117-121
      1. Roach SK, Kozarek RA, Raltz SL, Sumida SE. In vitro evaluation of integrity and sterilization of single-use argon beam plasma coagulation probes. Am J Gastroenterol. In press.

        • Kim-Deobald J
        • Kozarek RA
        • Ball TJ
        • Patterson DJ
        • Brandabur JJ
        • Raltz S
        Prospective evaluation of costs of disposable accessories in diagnostic and therapeutic ERCP.
        Gastrointest Endosc. 1993; 39: 763-765
        • Walker RS
        • Vanagunas AD
        • Williams P
        • Chodash HB
        therapeutic ERCP: a cost-prohibitive procedure?.
        Gastrointest Endosc. 1997; 46: 143-146
        • Cohen J
        • Haber GB
        • Kortan P
        • Dorais JA
        • Scheider DM
        • Cirocco M
        • et al.
        A prospective study of the repeated use of sterilized papillotomes and retrieval baskets for ERCP: quality and cost analysis.
        Gastrointest Endosc. 1997; 45: 122-127
        • O'Connor KW
        Disposable versus reusable ERCP equipment: the tip of the regulatory iceberg.
        Gastrointest Endosc. 1993; 36: 846-847
        • Yang R
        • Naritoku W
        • Laine L
        Prospective randomized comparison of disposable and reusable biopsy forceps in gastrointestinal endoscopy.
        Gastrointest Endosc. 1994; 40: 671-674
      2. Technology assessment status evaluation. Disposable endoscopic accessories.
        Gastrointest Endosc. 1993; 39: 878-889
        • Bruning LM
        Disposables v. reusables in OR practice; II: Weighing costs, risks, and wastes.
        Nurse Manag. 1992; 23: 72I-P
        • Sullivan P
        Speakers offer vastly different views on disposable health care products.
        Can Med Assoc J. 1990; 143: 1342-1345
        • Kozarek RA
        • Raltz SL
        • Merriam LD
        • Sumida SE
        Disposable versus reusable biopsy forceps: a prospective evaluation of costs.
        Gastrointest Endosc. 1996; 43: 10-13
        • Kozarek RA
        Coming clean on reuse of endoscopic equipment.
        Gut. 1998; 42: 155-156